Boiling water flow rate
The boiling water flow rate can be adjusted to
suit the installation or
Extended tube lengths will require the pump
speed to be increased.
1. To adjust, use the selection procedure as
described above in Steps 1, 2 and 3.
Press
SELECT. Shaded curser shows
2.
'Pump Speed 015'.
3.
Press
SELECT. '015' flashes.
Press
or
4.
decrease. Range is between 1 and 20.
5.
Press
SELECT.
6. Press
BACK twice to return to
normal display.
Calibrating
boiling
(Manually)
The boiling water temperature has been factory
calibrated. Because water boils at a slightly
lower temperature at elevated altitudes, the
factory-set temperature may be too high for
units installed at certain inland locations. If the
local altitude is greater than 500 metres above
sea level, a calibration cycle should be
performed.
The procedure is as follows:
1. Use the selection procedure as described
above, in Steps 1, 2 and 3.
2. Press
SELECT twice to select 'Calibrate
Boiling Water'.
3. Press
SELECT twice to begin cycle.
4. The unit will fill and heat (if not yet up to
operating
temperature
begins).
CAUTION: Steam will discharge from the
vent
outlet.
Once
temperature is established, the Quadra
recalibrates its internal settings and the
display panel returns to normal.
user preference.
buttons to increase or
water
temperature
before
cycle
correct
boiling
WARNINGS.
For continued safety of this appliance it
must be installed, operated and maintained
in accordance with the manufacturer's
instructions.
-
Your appliance should be installed by a
suitably qualified tradesperson.
-
For correct operation of this appliance it is
essential to observe the instructions as
outlined in this booklet.
-
Do not use this appliance with water that is
microbiologically unsafe or with water of
unknown
quality
disinfection before or after the system.
Systems certified for cyst reduction may be
used on disinfected water that may contain
filterable cysts.
-
Filter replacement must be performed at
intervals of not more than 12 months.
-
Use this appliance only as directed in these
instructions and only for its designed
purpose.
-
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless
they have been given supervision or
instruction concerning use of the appliance
by a person responsible for their safety.
-
Children should be supervised to ensure
that they do not play with the appliance.
DANGER: The operation of the thermal
-
cut-out indicates a possibly dangerous
situation. Do not reset the thermal cut-out
until the water heater has been services by
a qualified person.
WARNING: Do not connect any restrictor
-
or pressure relief device to the vent pipe of
this water heater if installed.
-
If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified persons in order
to avoid a hazard.
-
New hose-sets supplied with the appliance
are to be used and old hose-sets should not
be used.
without
adequate
9