If any of the standard accessories are lost or damaged, you can order a replacement for the
IRX1. Please quote the following part numbers when placing an order:
Part No.
Accessory Description
(1) 110-00003-001
AC/DC adapter
(2) 100-00006-001
IRX1 Operation Manual (This guide)
To place an order, please call Effigis at + 1 888 495-6577 or + 1 514 495-0018
1
8
2
CPAT FLEX (IRX1)
3. Installation
3.1 Rack Mounts Installation
CAUTION!
Leave space for front, back and lateral ventilation.
3.2 Connecting RF Entries
The RF entries are connected directly the return nodes tap. The maximum RF level entry is 40
dBmV per RF input. This is however the total RF level between 5 MHz and 45 MHz.
It is recommended to have a minimum of pads without having the frequency band (5-45
MHz) power to go over 40 dBmV per RF input.
If you want to combine nodes on the same RF entry, be aware that the IRX1 sensitivity
performance might be affected: since the IRX1 tries to detect ingress, the incoming digital
ingress signal is not always at the same level. Also, the measured value does not take into
account the pads.
CAUTION!
Levels over this limit can distort the signal or damage the receiver's RF front-
end. Contact the CPAT technical support for more information.