CPG 351FFOP50L Servicehandleiding - Pagina 4
Blader online of download pdf Servicehandleiding voor {categorie_naam} CPG 351FFOP50L. CPG 351FFOP50L 13 pagina's. Open pot fryers
Ook voor CPG 351FFOP50L: Gebruikershandleiding (16 pagina's)
Service Manual
351FFOP40N, 351FFOP50N, 351FFOP40L, 351FFOP50L
Part Testing
CAUTION: Components Can Be Hot
Follow these pre-maintenance steps before servicing
your Cooking Performance Group Floor Fryer
PRE-MAINTENANCE:
1.
Turn thermostat to the "OFF"
position (Fig. 1)
2.
Turn knob, on combination gas valve,
to the "OFF" position, align with
"RED" dot (Fig. 2)
3.
Turn off gas supply to unit (Fig. 3)
(Supplied by others)
4.
Allow unit to cool as needed
GAS COMBINATION VALVE:
•
Thermopile voltage with pilot light on
= 250 - 750 millivolts DC with thermostat
in "OFF" position (Fig. 4)
•
If too low, adjust pilot light flame strength,
see below
•
Knob in "ON" position, Thermostat in "ON"
position, coil voltage should be higher than
120 millivolts
•
If the coil voltage is below 120 millivolts DC,
replace combination valve
GAS COMBINATION VALVE
ADJUSTMENTS:
Adjusting Pilot Light Strength
1.
Remove screw cap covering pilot adjustment
screw, located next to the pilot light gas hose,
with a flat head screwdriver (Fig. 5)
2.
With a small flat head screwdriver, turn the
adjusting screw to increase or decrease pilot
light strength as needed
Counterclockwise = Increase
Clockwise = Decrease
3.
Reinstall cover cap when correct strength has
been reached
Pilot light strength check
1.
Pilot light should have a minimum
millivolt reading of 250, 500 or more is
recommended (Fig. 6)
4
FIG. 1
FIG. 3
FIG. 5
.
FIG. 2
FIG. 4
FIG. 6
www.cookingperformancegroup.com