Allied Telesis SwitchBlade AT-SB4104-80 Handleiding voor snelle installatie - Pagina 4

Blader online of download pdf Handleiding voor snelle installatie voor {categorie_naam} Allied Telesis SwitchBlade AT-SB4104-80. Allied Telesis SwitchBlade AT-SB4104-80 11 pagina's. Switchblade chassis and fan tray

Allied Telesis SwitchBlade AT-SB4104-80 Handleiding voor snelle installatie
4
Blank faceplates for all but one switch controller bay and one line card bay
(pre-installed at factory). That is, eight faceplates for the SwitchBlade 8 and
four faceplates for the SwitchBlade 4.
One blank faceplate for each PSU bay (pre-installed at factory).
Two rack-mount brackets (pre-installed at factory).
One 19 inch rack-mount kit.
Two RS-232 DB9 cables for connecting switch controller RS-232 ASYN0
ports to a terminal or PC.
Two Ethernet patch cables for connecting switch controller RJ-45 ETH0
ports to a terminal or PC.
One SwitchBlade Documentation and Tools CD-ROM (which includes the
complete SwitchBlade documentation set and utilities).
One SwitchBlade Chassis and Fan Tray Quick Install Guide.
One Safety and Statutory Information booklet.
One warranty card.
One cable manager with four wire loops (with the SwitchBlade 8 only).
One rack crossbar (to support the chassis's weight during installation).
Related items that can be purchased separately:
Blank faceplates for switch controller and line card bays (AT-SB4193).
Blank faceplates for PSU bays (AT-SB4192).
Fan trays (AT-SB4152 for the SwitchBlade 8 or AT-SB4151 for the
SwitchBlade 4).
Blank faceplates for fan tray bays (AT-SB4191 for the SwitchBlade 8 or
AT-SB4194 for the SwitchBlade 4).

Selecting A Site

The chassis can be installed in a standard 19-inch rack or on a level surface
such as a sturdy bench. When installing the chassis, choose a site that:
allows adequate airflow around the chassis and its vents.
is free of dust and moisture.
will allow the chassis and its components to operate within a temperature
range of 0 to 40º C (32 to 104º F) and a humidity range of 5 to 95% non-
condensing.
has a reliable and earthed (grounded), preferably dedicated and filtered
power supply circuit.
does not expose cabling to sources of electrical noise, such as radios,
transmitters, broadband amplifiers, power lines, electric motors, and
fluorescent fixtures.
allows easy access to the chassis's power and cable connections.
will allow all related network devices to be connected to the chassis
without exceeding maximum cable length limitations. See the SwitchBlade
Hardware Reference for cable length specifications.
SwitchBlade Chassis and Fan Tray
C613-04029-01 REV C