Avsl 170.665UK Gebruikershandleiding - Pagina 4
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Avsl 170.665UK. Avsl 170.665UK 12 pagina's. Digital speaker management system
Ook voor Avsl 170.665UK: Gebruikershandleiding (12 pagina's)
Panel Operation
Input Parameter Setting
Pressing a Mute/Edit button will Mute or un-mute that specific input.
Press & hold the MUTE/EDIT key for IN A or IN B for 3 seconds to enter edit mode.
Using the BACK and NEXT navigation buttons will step through the various menu options.
1. Input Name
Parameter 1 rotary control selects the letter or figure
Parameter 2 rotary control moves to the next or previous character
Press ENTER to confirm when the name is set as required
2. Input Delay
Delay 0-1000ms / 0-346m / 0-1134.88ft (independent per channel)
Parameter 1 rotary control performs fine adjustment
Parameter 2 rotary control performs coarse adjustment
3. Input Polarity
Polarity [+] Normal / [-] Inverted (independent for each channel)
Parameter 1 rotary control toggles between + and - polarity
4. Input Gain
Gain -40 to +6dB in 0.1dB steps (independent for each channel)
Parameter 1 rotary adjusts the Gain value
5. Input EQ
Input EQ1 - EQ8 (8 independent EQs for each channel)
Press BACK or NEXT buttons to step through EQ1 to EQ8
Parameter 1 rotary selects the filter type:
Parametric (PEQ), High-Shelf (Hi-S) or Low-Shelf (Lo-S)
Press ENTER to confirm the filter type and move down to parameter settings.
Parameter 1 rotary control adjusts the cutoff frequency (20Hz to 20kHz)
Parameter 2 rotary control adjusts the gain (-30 to +15dB)
Parameter 3 rotary control selects bandwidth/slope (0.05-3.00oct or 6-12dB/oct)
Press ENTER to confirm parameter settings
6. Noise Gate
Noise gate threshold -120 to +10dBu
Parameter 1, 2 or 3 rotary controls adjust the gate threshold
4
170.665UK User Manual