Avtron K711D36027 Handmatig - Pagina 13
Blader online of download pdf Handmatig voor {categorie_naam} Avtron K711D36027. Avtron K711D36027 17 pagina's.
Maintenance
To provide long equipment life and to reduce the chance of electric shock, fires, and personal injury,
good maintenance procedures must be used.
CONSIDERATIONS section of this manual.
The following examples of scheduled maintenance procedures are not intended to be all-inclusive,
but must be accomplished to maintain the equipment in a good, safe condition. All maintenance
work must be performed only by qualified personnel.
*************************************************************
Personal injury from electrical shock or from the moving fan blade
may result if ALL sources of power are not disconnected. Refer to
the SAFETY CONSIDERATIONS section of this manual.
Eye protection should be worn when cleaning the unit with
compressed air.
*************************************************************
DAILY
1.
Remove any restrictions to the airflow through the Load Bank.
2.
Check the screens to make sure that no objects have blocked or entered the openings. If
freezing conditions exist (below 32F or 0C) and freezing rain, sleet, or snow block the
exhaust hood/duct/louver, the following special precautions must be taken. Clear area
around exhaust opening.
3.
Verify that the airflow is in the proper direction.
4.
Assure that there is no recirculation of the exhaust air through the Load Bank.
THREE MONTHS
SECTION V
MAINTENANCE
Before servicing, review the SAFETY
W A R N I N G
5-1
Avtron Load Bank • Part Number K711D36027