Dell POWER EDGE SC1430 Informatie-update

Blader online of download pdf Informatie-update voor {categorie_naam} Dell POWER EDGE SC1430. Dell POWER EDGE SC1430 22 pagina's. Dell poweredge sc1430 servers: owners manual

Dell POWER EDGE SC1430 Informatie-update
Dell™ PowerEdge™ SC 1430 Systems
Information Update
Installing a Fourth Hard Drive
A fourth hard drive requires an optional hard-drive carrier with a cooling fan. Installation steps are
described in "Installing an Optional Fourth Hard Drive" in your Hardware Owner's Manual. When
performing this procedure, note the following additional information:
NOTE:
If a second processor is installed in your system, do not route the fan cable through the narrow space
between the air baffle and the processor heat sink. Open the processor access door on the air baffle and push
the fan cable underneath the heat sink fins to prevent damage to the cable.

System Messages

Table 1 provides an additional system message that your system may display on the screen.
See "System Messages" in your Hardware Owner's Manual for information about
other system messages.
Table 1. System Messages
Message
The FBD link to the
following DIMM failed
to train: DIMM x
Causes
Faulty or improperly installed
memory module.
October 2006
Corrective Actions
Ensure that only Dell-qualified memory
is used. Dell recommends purchasing
memory upgrade kits directly from
www.dell.com or your Dell sales agent
to ensure compatibility.
Reseat memory modules. See "Memory"
in your Hardware Owner's Manual.
If the problem persists, see
"Troubleshooting System Memory"
in your Hardware Owner's Manual.