Section
Enabling WOL under Red Hat Enterprise
Linux
versions 4 and later and SUSE
®
Linux Enterprise Server versions 9 and
later
 
NICs and LOMs from Dell have WOL disabled by default. Having more than 
one device enabled for WOL in a system can overload the 3.3‐volt auxiliary 
power supply and cause it to malfunction.  Dell strongly recommends that only 
one device be enabled for WOL per system. To enable WOL, create a DOS‐
bootable floppy and copy the utility, listed in the Tools section above, specific to 
the WOL device to it from the Dell Open Management Server Assistant or 
download it from http://support.dell.com.  
 
The steps to Enabling WOL under Red Hat Enterprise Linux versions 4 and later 
and SUSE Linux Enterprise Server versions 9 and later are as follows: 
 
1. Login  to the BASH shell with root privileges.  If the most recent Dell 
provided drivers are not installed, install them. Run 'ethtool ethX' where 
'ethX' is the name and instance of the desired WOL network interface.  The 
WOL capabilities and current default settings will be displayed in the 
output. 
 
2. Run 'ethtool ethX –s wol g' to enable Magic Packet WOL, where ethX is the 
name and instance of the desired WOL network interface. 
3. Halt Linux and shut the system off.  The connection LED on the NIC and 
switch or hub will remain on, indicating the NIC is monitoring the network 
for wake up packets directed to its MAC address. 
October 2007
a. The ethtool man pages have more information on settings and 
meanings of the settings. 
b. If the default settings show WOL disabled (as they will by default as 
shipped from Dell) then following steps 1 and 2 in the Out‐of‐Box 
WOL instruction section will change the default setting. 
c.
Enabling WOL with ethtool when the default is disabled will not 
persist across reboots, meaning that shutting down and performing 
WOL once, then shutting down again and attempting WOL will not 
be successful without running ethtool again to enable WOL.  The use 
of a startup script can enable WOL on each subsequent reboot if 
desired, or changing the default from the DOS based utilities. 