Table 1-5. Power Control Options
Radio Button
Reset Server
Power Off Server – Immediate
Power Off Server – Orderly Shutdown
Power On Server
Power Cycle Server
Console Redirection
The most powerful feature of the Dell Remote Management Controller is the ability to redirect the
host system's console, managing the host system as though it were physically in front of you. Note
the following about console redirection:
You can run a maximum of four simultaneous redirection sessions.
®
The Java
Video Viewer (version 1.5.15 or later) is required to run the console redirection. If
the BMC detects that the video viewer is not installed, you are prompted to install it.
The recommended display resolution on the management station is at least 1280 x 1024
pixels at 60Hz with 32 bit color. If the resolution does not meet this minimum, you will be
unable to view the console in full screen mode.
Before using console redirection, verify that your mouse mode is correct. See "Mouse Mode".
To start a remote console session from the Console Redirection window, click the Java Console
button. This launches the redirection console via the JViewer Java applet. For further information
on remote console sessions, see "Running Virtual Media".

Maintenance

The Maintenance menu selection allows you to upgrade to the latest firmware version through the
GUI. The following data is included in the BMC firmware package:
Compiled BMC firmware code and data
Web-based user interface, JPEG, and other user interface data files
Default configuration files
NOTE:
The firmware update retains the current BMC settings.
NOTE:
You can also update the firmware using trivial file transfer protocol (TFTP). See
"Updating Firmware Using the TFTP Flash Interface".
Description
Reboot server without powering off (warm boot).
Powers off the server.
Shuts down the server.
Powers on the server.
Powers off, then reboots the server (cold boot).
Using the Baseboard Management Controller
13