Dell PowerEdge M420 Gebruikershandleiding - Pagina 21

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Dell PowerEdge M420. Dell PowerEdge M420 26 pagina's. Dell poweredge blade servers getting started guide
Ook voor Dell PowerEdge M420: Informatie-update (38 pagina's), Release-opmerkingen (27 pagina's), Handmatig (25 pagina's), Gebruikershandleiding (23 pagina's), Belangrijke informatie Handleiding (35 pagina's), Handleiding bijwerken (32 pagina's), Handleiding bijwerken (28 pagina's), Gebruikershandleiding (22 pagina's), Aan de slag handleiding (12 pagina's), Handmatig (38 pagina's), Technisch handboek (46 pagina's), Technisch handboek (48 pagina's), Portfolio Handleiding (27 pagina's), Aan de slag handleiding (14 pagina's), Aan de slag handleiding (12 pagina's)

Dell PowerEdge M420 Gebruikershandleiding
Dell 10Gb Ethernet Pass Through II
Step 10.Login to the 10GbE PTM CLI as admin. Run:
# login admin
Step 11.To confirm that all PhyX® chips have the same firmware version, run the command:
& show image ver
Software image version: X.X.XXX-<date stamp>
Component #1 FW version: Y.Y.YYY
Component #2 FW version: Y.Y.YYY
Component #3 FW version: Y.Y.YYY
&
4.2

CPU Software Update

This procedure describes how to update CPU SW using a .bin binary file.
Step 1. Connect to the 10GbE PTM using an SSH Client as described in
the 10GbE PTM CLI," on page
Step 2. From the CMC command line, enter the following command:
$ racadm chassisaction -m [10GbE PTM device Name] powercycle
Example according to section 2 output:
$ racadm chassisaction -m switch-2 powercycle
Note You must connect before the 15-second countdown expires in order to interrupt
Step 3. Connect to the 10GbE PTM CLI. Enter:
$ connect switch-<n>
Where <n> is the number of the switch, 2 in our example.
Note Press any key before the 15-second countdown expires in order to get to the boot
You should see the banner "Welcome to Dell PTM Boot loader console". Note that the
banner displays the current CPU FW build. If you do not succeed, then you need to exit
the 10GbE PTM CLI (enter "exit"), and then go back to Step 1 of this section.
Step 4. From the Boot loader command line, run:
# cpufwupdate
8.
the Boot Loader.
loader command line.
Rev 1.00
Section 2, "Connecting to
21