Dell PowerEdge R610 Onderhoud en probleemoplossing - Pagina 20

Blader online of download pdf Onderhoud en probleemoplossing voor {categorie_naam} Dell PowerEdge R610. Dell PowerEdge R610 24 pagina's. Poweredge series
Ook voor Dell PowerEdge R610: Documentatie bijwerken (14 pagina's), Handleiding bijwerken (32 pagina's), Informatie-update (14 pagina's), Informatie-update (38 pagina's), Handleiding bijwerken (44 pagina's), Installatie-instructies (2 pagina's), Handmatig (10 pagina's), Instructies voor installatie van hardware (2 pagina's), Handleiding bijwerken (14 pagina's), Portfolio Handleiding (27 pagina's), Gegevensblad (2 pagina's)

Dell PowerEdge R610 Onderhoud en probleemoplossing
Maintaining and Troubleshooting the Dell
Code
Text
E1715
Fatal I/O error.
E1716
Chipset IERR Bus
## Dev ## Function
##.
E1717
CPU ## internal
error.
E171F
PCIE Fatal Err B##
D## F##
PCIE Fatal Err Slot
#
E1810
HDD ## Fault
E1811
HDD ## Rbld Abrt
E1812
HDD ## Removed
E1A11
PCI Riser hardware
& configuration
mismatch
E1A12
PCI Riser not
detected
E1A14
SAS Cable A
Maintaining and Troubleshooting the Dell
20
PowerEdge
R610 Server
Causes
but is unable to determine its
origin.
The system BIOS has
determined there has been
an error in the system.
The system BIOS has
reported a chipset internal
error that resides in bus ##,
device ##, function ##.
The system BIOS has
determined that the specified
processor has had an
internal error.
The system BIOS has
reported a PCIe fatal error on
a component that resides in
PCI configuration space at
bus ##, device ##, function
##.
The system BIOS has
reported a PCIe fatal error on
a component that resides in
the specified slot.
The SAS subsystem has
determined that hard drive ##
has experienced a fault.
The specified hard drive has
experienced a rebuild abort.
The specified hard drive has
been removed from the
system.
PCIe risers are not
configured correctly. Some
invalid configurations prevent
the system from powering
on.
One or all of the PCIe risers
is missing. The prevents the
system from powering on.
SAS cable A is missing or
bad.
PowerEdge
Comments on this document? [email protected]
Corrective action
Call Avaya Services.
Call Avaya Services.
Call Avaya Services.
Reseat all PCIe cards, then reboot
the system. If the problem persists,
escalate for possible server
replacement.
Remove the front bezel and check the
top LED on the hard drives. If LED is
off or flashing green, then amber,
then off or flashing amber 4 times per
second, the hard drive is probably
failing. Escalate for possible hard
drive replacement.
Information only.
Reinstall the expansion-card riser.
Reseat the NIC. If problem persists,
replace the server.
Reinstall the missing riser card(s).
Escalate for possible server
replacement.
R610 Server
Table continues...
November 2010