The ISO-FLAMES gas log set must be installed by a qualifi ed professional service technician. Instructions
must be followed carefully to ensure proper performance and full benefi t from the gas log set. Check to be
sure the log set is designed and labeled for the type of gas (natural or propane gas) supplied to the
fi replace. Fireplace fl oor must be level, clean, and smooth.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only
parts specifi cally approved with this appliance may result in property damage or
personal injury.
1. MAKE SURE THE FIREPLACE GAS SUPPLY IS
TURNED OFF.
2. Place the burner system in the fi replace. Center the
burner toward the rear of the fi replace. (Reference Fig.
8-2 for orientation.)
3. Locate the gas-supply stub inside the fi replace and
remove the cap, if attached (see Fig. 8-1).
4. Use pipe compound resistant to all gases or Tefl on
tape to attach the supplied elbow to the gas-supply
stub. Then attach the fl ex connector (coming off of the
burner system) to the elbow (see Fig. 8-1).
5. LEAK TEST: Turn on the fi replace gas supply, and test
at all connections for leaks using the appropriate soapy
water solution. If bubbles appear, a leak is present. Turn
off the gas and tighten at all connections. Repeat until
no leaks are present. If a leak persists, turn off the gas
supply and contact the local gas company or dealer.
NEVER USE A FLAME TO CHECK FOR LEAKS.
6. Place the remote receiver box at the right front corner
of the fi replace. Be sure to run its wire in between the
two grate legs on the right side of the burner system,
and that the wire remains away from the burner system
and its fl ame during operation. (See Fig. 8-2.)
Note: Alternately; the box can be placed at the rear
right corner of the burner system. Be sure
to place its wire towards the back so that it
remains away from the burner system and its
fl ame during operation. (See Fig. 8-3.)
If optional wall switch was purchased separately; refer
to the instructions supplied with the wall switch for
installation.
For all valves, the air MUST be purged from the gas line before the pilot will light and burn properly. The
time needed to purge will depend on the length of the gas line to the unit and the amount of time since
the unit or gas line was last used. It may take several minutes before all the air is purged and the pilot
will light and burn properly. Reference the LIGHTING INSTRUCTIONS section in this manual.

BURNER INSTALLATION

IMPORTANT
8
Gas-supply stub
Fig. 8-1 Connect gas supply
Fig. 8-2 Remote receiver box location
Fig. 8-3 Alternate receiver box location
Flex connector
Elbow