Power
AC Power Supply (per power supply)
Wattage
Heat dissipation
NOTE: Heat dissipation is calculated
using the power supply wattage
rating.
Voltage
NOTE: This system is also designed
to be connected to IT power
systems with a phase to phase
voltage not exceeding 230 V.
Battery
Coin-cell battery
Physical
Height
Width
With rack latches
Without rack latches
Depth (excludes bezel)
Weight (maximum)
Weight (empty)
Environmental
NOTE: For additional information about environmental measurements for specific system configurations, see
dell.com/environmental_datasheets.
Temperature
Operating
Storage
Relative humidity
550 W
2132 BTU/hr maximum (redundant, 550 W power supply)
100 V AC to 240 V AC, autoranging, 50 Hz/60 Hz
3 V CR2032 Lithium coin cell
42.8 mm (1.68 inch)
482.4 mm (18.99 inch)
434.0 mm (17.08 inch)
607.0 mm (23.9 inch)
19.3 kg (42.55 lb)
16.33 kg (36 lb)
Continuous operation: 10 °C to 35 °C at 10% to 80% relative humidity
(RH), with 26 °C max dew point. De-rate maximum allowable dry bulb
temperature at 1 °C/300 m above 900 m (1°F per 550 ft).
NOTE: For information on supported expanded operating
temperature range and configurations, see support.dell.com/
manuals.
–40 °C to 65 °C (–40 °F to 149 °F) with a maximum temperature
gradation of 20 °C per hour