mode.
Function Code F — Write Performance Test
Causes the tape drive to perform tests to ensure that the drive can read from and write to tape. This diagnostic performs fewer tests than the Run Tape
Drive Diagnostics test (Function Code 1). The tape drive takes approximately 3 minutes to run the test. The Fast Read/Write Test is not as comprehensive a
test and is not recommended for isolating errors between the drive and the media.
Attention: Data on the suspect tape will be overwritten.
1. Ensure that there is no cartridge in the drive.
2. Press the eject button three times within an interval of 2 seconds. The status light becomes solid amber, which means that the drive is in
maintenance mode.
3. Press the eject button once per second until
it redisplays.
4. To select the function, press and hold the eject button for 3 seconds. After you select the function,
for a cartridge. Within 60 seconds, insert the suspect data cartridge (or the tape drive exits maintenance mode). After you insert the cartridge,
flashes and the test begins.
If no error is detected, the test begins again and runs for a maximum of ten times. Each loop takes approximately 3 minutes to run. After the
¡
tenth loop, the test stops and the drive automatically exits maintenance mode.
If an error is detected, the tape drive displays an error code. Once the cartridge is manually ejected and removed, the tape drive exits
¡
maintenance mode.
To halt the diagnostic at the end of the current 3-minute test loop, press the eject button once. The drive acknowledges the request by slowing
¡
the length of time that the currently displayed character flashes on the single-character display (from twice per second to once per second.)
The diagnostic continues to the end of its loop and then stops. The tape drive then rewinds, unloads the cartridge, and exits maintenance
mode.
To halt the diagnostic immediately and terminate the test that is running, press the eject button twice. The tape drive rewinds, unloads the
¡
cartridge, and exits maintenance mode.
Function Code H — Test Head
Causes the tape drive to perform the Head Resistance Measurements test and a Write/Read test (on the center of the tape). The drive runs these tests to
ensure that the tape drive's head and tape-carriage mechanics are working correctly. The tape drive takes approximately 10 minutes to run the test.
1. Ensure that there is no cartridge in the drive.
2. Press the eject button three times within an interval of 2 seconds. The status light becomes solid amber, which means that the drive is in
maintenance mode.
3. Press the eject button once per second until
it redisplays.
4. To select the function, press and hold the eject button for 3 seconds. After you select the function,
for a cartridge. Within 60 seconds, insert a scratch data cartridge (or the tape drive exits maintenance mode). After you insert the cartridge,
flashes and the test begins:
If no error is detected, the test begins again and runs for a maximum of ten times. Each loop takes approximately 10 minutes to run. After the
¡
tenth loop, the test stops and the drive automatically exits maintenance mode.
If an error is detected, the tape drive displays "5", unloads the tape cartridge, and exits maintenance mode.
¡
To halt the diagnostic at the end of the current 10-minute test loop, press the eject button once. The drive acknowledges the request by
¡
slowing the length of time that the currently displayed character flashes on the single-character display (from twice per second to once per
second.) The diagnostic continues to the end of its loop and then stops. The tape drive then rewinds, unloads the cartridge, and exits
maintenance mode.
To halt the diagnostic immediately and terminate the test that is running, press the eject button twice. The tape drive then rewinds, unloads
¡
the cartridge, and exits maintenance mode.
Function Code J - Fast Read/Write Test
Approximate Run Time = 5 minutes
Total Number of Loops = 10
Function Code
performs tests to ensure that the drive can read from and write to tape.
The diagnostic loops ten times. Press the eject button to stop the diagnostic and exit maintenance mode. Pressing the eject button once will abort the test
at the end of the current test loop. Pressing the eject button twice will abort the test immediately.
Attention: For this test, insert only a scratch (blank) data cartridge or a cartridge that may be overwritten. During the test, the drive overwrites the data on
the cartridge.
1. Ensure that there is no cartridge in the drive.
2. Press the eject button three times within an interval of 2 seconds. The status light becomes solid amber, which means that the drive is in
maintenance mode.
3. Press the eject button once per second until
redisplays.
4. Press and hold the eject button for three or more seconds, then release it to select the function. The single-character display changes to a flashing
.
5. Within 60 seconds, insert a scratch data cartridge that is not write-protected.
NOTE: If you wait longer than 60 seconds to load a cartridge, the drive will automatically exit maintenance mode. If you insert a write-protected
cartridge, the tape drive will display a
drive will exit maintenance mode.
After you insert the cartridge, the single-character display changes to a flashing
Note: If you inserted an invalid cartridge, error code
manually ejected. Once ejected, the tape drive exits maintenance mode.
If no error is detected, the test will loop and begin again. To stop the loop, press the eject button for one second and release. When the loop
¡
appears in the single-character display. If you cycle past
appears in the single-character display. If you cycle past
appears in the single-character display. If you cycle past
and retain the cartridge until it is manually ejected. Once the cartridge is ejected and removed, the tape
appears in the single-character display. The tape drive retains the cartridge until it is
, continue to press the eject button until
flashes. When
, continue to press the eject button until
flashes. When
, continue to press the eject button until it
, and the tape drive runs the tests.
flashes, the drive is waiting
flashes, the drive is waiting