5.9 Field Replaceable Units (FRU)

Hot swap HDD and SSD, Power Supply Units (power supply/cooling fan modules), Enclosure
Management Modules (EMMs), Control Panel and Backplane are the primary field replaceable units on
the Dell™ PowerVault™ MD1200 and MD1220.
NOTE: For additional detailed instructions on installing and removing enclosure components, refer to
the PowerVault™ MD1200 and MD1220 Hardware Owner's manual and Getting Started Guide at
support.dell.com under manuals.

6 Environmental

6.1 Power Supply Specifications

The PowerVault™ MD1200 and MD1220 power supply is rated at 600 W. It operates on input voltages
ranging from 100 – 240 V, auto-switching to the sensed line level.
EMC classification is Light Industry
FCC classification is Class A
** Available in Q3 2010
Figure 13. Connecting a Mini-SAS Cable