Dell EMC PowerSwitch S6100-ON Installatiehandleiding - Pagina 43
Blader online of download pdf Installatiehandleiding voor {categorie_naam} Dell EMC PowerSwitch S6100-ON. Dell EMC PowerSwitch S6100-ON 48 pagina's.
![Dell EMC PowerSwitch S6100-ON Installatiehandleiding](/uploads/products/server2/3222288/3222288.png)
This topic lists the S6100–ON specifications.
CAUTION:
Operate the product at an ambient temperature not higher than 113°F (45°C).
CAUTION:
Lithium Battery Caution: There is a danger of explosion if the battery is incorrectly replaced.
Replace only with same or equivalent type of battery. Dispose of the batteries according to the manufacturer's
instructions.
NOTE:
For RoHS information, see
Topics:
•
Chassis physical design
•
IEEE standards
•
Agency compliance
•
USA Federal Communications Commission (FCC) statement
•
European Union EMC Directive Conformance statement
•
Japan: VCCI Compliance for Class A Equipment
•
Korean Certification of Compliance
•
Safety Standards and Compliance Agency Certifications
•
Electromagnetic Compatibility (EMC)
•
Product recycling and disposal
Chassis physical design
Table 10. Chassis physical design
Parameter
Height
Width
Depth
Chassis Weight with Factory-Installed Components
Rack Clearance Required
Table 11. Environmental Parameters
Parameter
Operating Temperature
Operating Humidity
Storage Temperature
Storage Humidity
Thermal Output
Restricted Material
Compliance.
Specifications
3.50 inches (88.9 mm)
17.1 inches (434.3 mm)
18 inches (457.2 mm)
44 lbs (20 kg)—with two PSUs and four I/O modules
Front: 5 inches (12.7 cm)
Rear: 5 inches (12.7 cm)
Specifications
32° to 113°F (0° to 45°C)
5 to 95 percent (RH), non-condensing
–40° to 158°F (–40° to 70°C)
5 to 95 percent, non-condensing
Typical: 1170.4 BTU/hr (343 W)
Maximum: 3057.3 BTU/hr (896 W)
Specifications
Specifications
10
43