Dell MXG610s Installatiehandleiding - Pagina 8
Blader online of download pdf Installatiehandleiding voor {categorie_naam} Dell MXG610s. Dell MXG610s 17 pagina's. Fibre channel switch module
Ook voor Dell MXG610s: Installatiehandleiding (13 pagina's)
You hear a click when the switch module is locked in the blade server chassis I/O
module bay. If the power is on in the blade server chassis, locking the switch module in
the module bay provides power and turn-ons the switch module and the LEDs.
The switch module then runs POSTs. These tests can take up to two minutes to
complete. After the power/status LED light is steady green for at least two minutes,
the module is ready to use.
4
Start from port 0, then port 17, and then the rest of the ports when cabling the SFP+
ports.
If you use QSFP ports instead of SFP+ ports, transfer the port license from port 0 and
17 to the desired QSFP ports. The QSFP ports must be unused and no additional port
licenses are available. Ports 0 and 17 are prelicensed at the factory.
You are now ready to insert more SFP+/QSFP optical transceivers, if needed. Be sure to
use only Brocade-branded SFP+/QSFP optical transceivers. The FC switch module does
not recognize unapproved products.
Serial connection
To log in to the switch module through the serial connection on the front panel, port-side
view, perform the following steps:
1
Connect the console cable with the micro-USB connector to the console port on the
switch module and to a USB port on the workstation.
2
Disable any serial communication programs running on the workstation such as
synchronization programs.
3
Open a terminal emulator application such as PuTTY, XShell, or SecureCRT on a
Windows PC, or TERM, TIP, or C-Kermit in a LINUX environment. Configure the
application as follows:
•
In a WIndows environment, use the following values:
– Bits per second—9600
– Databits—8
– Parity—None
– Stop bits—1
– Flow control—None; must be disabled on the host side
NOTE:
to a remote terminal. You must disable flow control on the customer-side
remote terminal server in addition to the host-side clients.
8
MXG610s Setup Guide
Flow control is not supported on the serial connection when attached