Dell S4248FB-ON Installatiehandleiding - Pagina 27

Blader online of download pdf Installatiehandleiding voor {categorie_naam} Dell S4248FB-ON. Dell S4248FB-ON 47 pagina's. S4200-on series
Ook voor Dell S4248FB-ON: Installatiehandleiding (29 pagina's)

Dell S4248FB-ON Installatiehandleiding
Figure 15. Front rack installation
NOTE:
Do not the use the mounted Ready-Rails as a shelf or a workplace.
3
Tighten the two thumb screws and rack screws.
To remove the switch from the rack or cabinet, press in the two side-release bars on the switch at the same time and slide the switch
forward.

Ground cable

NOTE:
For AC-powered switches, although the third conductor of the AC power cord provides a ground path, Dell EMC
recommends grounding your switch with a dedicated ground wire.
NOTE:
For DC-powered switches, the only way to safely ground your switch is to attach a dedicated ground wire.
Depending on the type of switch, to attach a ground cable to the switch, you need M3 or M4 screws.
The switch ships with one of the following two configurations:
One threaded hole using an M3 screw.
Two threaded holes using one of the two M4 screws.
In both configurations, the ground cable is not included. To properly ground the switch, Dell EMC recommends a one- or two-hole lug, M3
or M4 hole size. The ground lugs must be a UL-recognized, crimp-type lug.
CAUTION:
Grounding conductors
must be made of copper. Do not use aluminum conductors.
S4200-ON Series installation
27