Connecting the dispenser pumps
Connection points for 4 time controlled dispenser
pumps which can be operated without the
multi-function module are located behind the cover
next to the electrical connection point. See the wiring
diagram supplied.
Steam connection
Steam connection must only be carried out by an
authorised installer. See the installation instructions
supplied.
A steam solenoid valve, dirt trap and steam stop
valve should be installed on-site.
A steam valve and condensate trap are available to
order from your Miele Dealer or the Miele Spare Parts
Department.
Gas connection
This work must be carried out by an authorised
person in accordance with local and national safety
regulations. See the installation instructions supplied.
Installation and connection
The gas group to which the washer-extractor has
been set at the factory is given on the Gas Data label
on the rear of the machine.
If the machine is converted for a different gas group,
or to liquid gas, a conversion kit is required. This is
available from the the Miele Spare Parts Department.
When ordering please quote the model and serial
number of the appliance, as well as the gas type,
group and connection pressure in the country of
installation.
Please follow the installation instructions carefully. To
ensure safety, any conversion work must only be
carried out by an authorised technician, e.g. Gas
Safe registered in the UK.
,
Do not attempt to repair or work on gas-heated
appliances yourself. Repairs must only be carried
out by an authorised technician to ensure safety.
In the event of a fault please contact the Miele
Service Department.
After setting up and connecting the machine
successfully ensure that all removable outer
panels are correctly fitted back into position.
37