Miele PW 6207 Gebruiksaanwijzing - Pagina 32
Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Miele PW 6207. Miele PW 6207 40 pagina's.
Ook voor Miele PW 6207: Installatieplan (18 pagina's), Installatieplan (17 pagina's), Handmatig (48 pagina's)
Installation and connection
This machine must be installed by an authorised
technician only. In the UK any gas heated
machines must be installed by a Gas Safe
registered engineer.
,
This machine is not designed for washing
items which have been treated with dangerous or
flammable substances.
To avoid the risk of frost damage do not install this
machine in a room where there is a risk of frost
occurring.
Use a pallet lifter to move the machine around the
room.
Transport packaging must be carefully removed
using suitable tools.
Use a suitable lifting mechanism to lift the machine off
the transport pallet.
Do not install the machine on carpeted flooring as the
carpet pile can hinder the free flow of air into the
ventilation gaps at the bottom of the machine.
To ensure suitable access for future maintenance and
service work, please ensure that the minimum
distances between the machine and the wall
specified on the installation diagram are strictly
observed.
Minimum distance to wall for maintenance and
service work: approx. 400 mm.
The washer-extractor must be perfectly level to
ensure that it functions correctly.
The screw feet can be adjusted to align it.
The machine must not be moved without all the
outer panels in place.
32
Securing the machine
Gas heated washer-extractors must be secured to
the floor. Fixings are supplied with the machine.
Installation on a plinth
The washer-extractor can be installed on a plinth or a
raised concrete plinth.
The plinth must be secured to the floor.
Concrete plinth / Floor
Miele plinth