Installation instruction

Installation
Condensate
Machine feet
Electrical
connection
Non-return device
Steam condensor
External dosing
system (optional)
page 1 / 8
Observe installation instructions when installing machine.
This dishwasher is only suitable for commercial use.
Installation should only be carried out by authorized installers in
accordance with valid regulations, relevant standards and health and
safety codes!
Only use commercial grade cabinetry in the vicinity of this commercial
dishwasher as condensate may otherwise cause damage.
To ensure stability install the included floor bracket BBF-80 (Installation
Instructions Mat.no.: 09788890)
It is recommended to make electrical connection via a plug and socket
so that electrical safety checks can be carried out easily. The socket
must be accessible after machine installation.
With a fixed installation, this must be via a main switch to be provided
on site, which must completely isolate the machine from the power
supply with a contact gap of at least 1/8'' (3 mm).
If necessary, an equipotential bond with good contact connection must
be provided in accordance with all appropriate national and local
regulations.
Protection class IP21
Connection to a drinking water supply is permitted without
an additional non-return device.
Steam condensor (DK) requires its own cold water connection. Use the
supplied Y-adapter if only one cold water connection is available.
Connect up to two dosing systems at the rear panel for liquid cleaning
agent and rinse aid.
Installation plan PG 8061