Allmatic ACTION Instructies voor installatie - Pagina 5

Blader online of download pdf Instructies voor installatie voor {categorie_naam} Allmatic ACTION. Allmatic ACTION 5 pagina's. For tecno-cat

6. Enabling and desabling the pre-flashing, photocell test and the multi-user function.
To modify the status of any of these functions it is necessary to enable the setting mode. in the phase of learning the control unit automatically goes
through all possible functions in which it is possible to intervene. The led of the flashing light signals the selected function each time with a variable
number of flashings. The passage from a function to another one is executed automatically (it is enough to maintain always pressed the red button).
The control unit starts selecting the first function ( signaled by 1 flashing), successively, keeping pressed the red button you pass at the second func-
tion ( signaled by 2 flashings) and so on. To enable the setting / learning mode proceed as follows:
1. Raise the chain to its upper position (completely closed).
2. Press and keep pressed the red button
3. After 4 - 5 seconds the led of the flashing - light executes a series of 8 flashings (notifying the next entry to the learning mode). Once the series of
flashings end the control unit is in the learning mode. Do not release the red button yet.
4. Once individualized (through the number of flashings of the flashing-light led) the function that you want to modify, release the red button. In this
way the function is selected. Once selected the function, the control unit puts in evidence the setting by flashing with a slow frequence ( 1 fla-
shing /second) or with a rapid frequence ( 2 flashings / second) as pointed out on the next table:
No. of flashes
1
2
3
4
5
6
5. Press now the button ( see table) correspondant to the new status you wish set for the selected function. The frequency of flashing will vary ac-
cording to the chosen mode.
At this point it is possible to modify further functions or, if you have finished, go out from the setting phase. In case you want to modify other func-
tions, press and keep pressed the red button. After few seconds, the control unit will start again to select in sequence the several functions. Instead if
you want to exit from the learning mode, it is sufficient to bring the lever of the selector Sw1 in manual position, wait 1-2 sec and successively report
it in automatic position. In this way, the control unit gets out of the learning mode and prepares itself for the normal functioning.
6.1 Pre-flashing: The chain movement is always signalized by a pre-blinking, advising the user that the chain is next to move.
6.2 Multi-user function: During the opening phase of the chain, every other command is ignored. Once opened the chain (completely down, it is
possible to close it using the step-by-step command or using the automatic re-closure. During the closing phase, a step-by-step command blocks
and inverts the movement.
6.3 Photocell test: Every time the motor is switched on, the control unit automatically controls if the photocells are functioning properly.
This operation increases the security system. If a photocell is damaged (for instance output relay stuck) or in case of undesired photocell input short
circuit. This test is executed immediately after that the control unit has received an order of "moving", but before power is applied to the motor.

7. Problems and their solutions

Type of problem
On activating the opening command the automa-
tion does not move.
On activating the opening command the chain
moves for a brief time and then stops.
On activating the opening command, the automa-
tion moves to closure.
You cannot manage to enter into the remote con-
trol learning phase
You cannot manage to memorise the remote con-
trols
You cannot manage to enter into the opening/
closure programming mode. (run-time)
The control panel is powered but the gate does
not move.
GUARANTEE - In compliance with legislation, the manufacturer's guarantee is valid from the date stamped on the product and is restricted to the
repair or free replacement of the parts accepted by the manufacturer as being defective due to poor quality materials or manufacturing defects. The
guarantee does not cover damage or defects caused by external agents, faulty maintenance, overloading, natural wear and tear, choice of incorrect
product, assembly errors, or any other cause not imputable to the manufacturer. Products that have been misused will not be guaranteed or re-
paired. Printed specifications are only indicative. The manufacturer does not accept any responsibility for range reductions or malfunctions caused
by environmental interference. The manufacturer's responsibility for damage caused to persons resulting from accidents of any nature caused by our
defective products, are only those responsibilities that come under Italian law.
6-1622349 rev.3 28/03/2019
Selected function
Pre-flashing
Photocell Test
Multi-user setting
Reserved
Reserved
Reserved
Probable cause
Lack of electrical power supply
Burned fuse
Incorrect encoder connection
Jumper direction motor inverted
The chain is not completely closed (UP)
The type of set decoding in the control
panel does not correspond to the type of
remote control in use.
The chain is not completely closed (UP)
A normally closed input is not active
ITA
ENG
Flash
Yellow button
Slow= disabled
Fast= disabled
Slow= disabled
Solution
Check the presence of the electrical voltage and
all the connections to the electrical network.
Replace the fuse with a similar one.
Check the connections of the encoder's wires.
Invert the Jumpers.
Close the chain (in the manual). If the chain was
closed set selector S1 to manual, wait 1 second
and re-set it to automatic. Try again entering into
setting mode.
Check which decoding has been set and possibly
select that which corresponds to the remote con-
trol in use.
Close the chain (in the manual). If the chain was
closed set selector S1 to manual, wait 1 second
and re-set it to automatic. Try again entering into
setting mode.
Check the photocell, stop and limit switch input. If
not used they must be bridged to the common.
FRA
ESP
DEU
POR
Blue button
activation
deactivation
activation
deactivation
activation
deactivation
pag. 5 di 5