10. Adjusting of the motors velocity in slowing down
This procedure must ONLY be carried out by the installer and ONLY during the put in function of the system. For a correct programming, before
carrying out any modification, bring always back the door to the totally closed position.
With the door in movement check
the velocity of the door in slowing
down phase.
WARNING: it is indispensable to carry out, after adjusting the desired velocity in slowing down, a new programming of the strokes in
11. Adjusting the automatic reclosure time
This procedure must ONLY be carried out by the installer and ONLY during the setting up of the system. For a correct programming, before any
modification, bring always the gate back to the totally closed position.
With gate closed give a step by
step command and wait for
complete opening.
Turn the trimmer A. RE-CLOSURE TIME completely in clockwise
sense. In this way the automatic reclosure is disabled.
Turn the trimmer AUTOMATIC RECLOSING completely in anti-clockwise
sense to enable the photocells automatic reclosing. If the photocells
beam is not interrupted, the control unit re-closes itself after 2 min.
6-1622372
rev.5 04/02/2016
It is possible to turn the SLOW DOWN
VELOCITY trimmer in clockwise sense to
increase the velocity of the motors.
The velocity is too low
The velocity is too high
It is possible to turn the SLOW DOWN
VELOCITY trimmer in anti clockwise sense to
lower the velocity.
the case in which the slowing down phase is personalized.
Turn the trimmer A. RE-CLOSURE TIME in clockwise sense. In this
way the automatic reclosure time increases.
The Automatic re-closure
time is too short
The Automatic re-closure
time is too long
Turn the trimmer A. RE-CLOSURE TIME in anti-clockwise sense. In
this way the automatic reclosure time decreases.