Allmatic AV Handmatig - Pagina 4
Blader online of download pdf Handmatig voor {categorie_naam} Allmatic AV. Allmatic AV 6 pagina's. Control unti with extractible memory
6. Advanced programming:
FUNCTIONS SELECTION
By operating on the jumpers present on the central control panel it is possible to personalize the automation.
The table on the following page describes the working and the effect that the action on each single jumper
has on the central control panel.
N.
B.: DISCONNECT THE POWER SUPPLY EACH TIME THAT YOU OPERATE THE JUMPER!!!
IN ORDER TO MAKE THE PERSONALISATION PHASE EASIER IT IS AD-
VISABLE TO SET THE JUMPER BY REMOVING THE OPTIONAL ADDITIO-
NAL CARD.
J1
POS.1 POS.2
J2
POS.1 POS.2
J3
J4
CONDOMINIUM FUNCTION:
The opening mechanism starts with an impulse command when the gate is closed. Any other impulse command is ignored. Once completely
opened, the reclosure is commanded only by time. If this is not set, the gate remains open without possibility of closing again.
For this reason a preset reclosing time of 30 seconds has been considered.
The photocell is engaged to reload the entire reclosing time when the gate is open. If the photocell remains interrupted the gate does not restart.
During reclosure, an impulse command stops the unit and makes the automation totally reopen.
6-1622081
REV.12
23/09/2020
POS.1: The transmitter works in IMPULSE MODE. The memorised key runs these functions:
OPEN...STOP...CLOSE...STOP.
THE SECOND CHANNEL memorised BY THE TRANSMITTER manages the PEDESTRIAN mode. (In
this mode the transmitter cannot carry out either the deadman function or the normal working function).
POS.2: The OPEN/CLOSE FUNCTION, manages the automation acting on the 2 transmitter keys. The
first commands the gate to open, the second to close. J1 in position 2 has another possibility of perso-
nalising the central computer acting on jumper 2.
POS.1: Determines the NORMAL WORKING of the wall keys and the transmitter. By pressing the
open key the gate opens completely, pressing the key a second time blocks the gate. If it is necessary
to stop the movement it is necessary to press the key relative to the other direction, in this case the
close key. To close re-press the close key. The same applies to open the gate.
-In this J2 configuration the intervention of the photoelectric cells during closure blocks the
gate and inverts the movement.
POS.2: Determines the PERSON PRESENT function both with the keys on the wall and the transmitter
(if jumper 1 = POS.2). The automation begins to open or close for the precision time of the relative
transmitter button or the key.
-In this J2 configuration the intervention of the photoelectric cells stops the movement until the
obstacle has been removed. The movement will re-commence, either opening or closing as se-
lected.
OPEN: The central computer allows FIXED CODE transmitter setting.
IN ORDER TO PASS FROM FIXED CODE TO VARIABLE AND VICE VERSA IT IS NECESSARY TO
RESET THE CONTROL PANEL!
CLOSED: The central computer allows VARIABLE CODE transmitter setting. The closure of the jumper
DECODE gives another possibility of personalisation by acting on the jumper type VARIABLE CODE.
Condominium function:
The unit is provided with a deactivated master function.
The master function is activated and deactivated by using jumper J4.
J4 CLOSED = CONDOMINIUM FUNCTION ACTIVATED
J4 OPEN = CONDOMINIUM FUNCTION DEACTIVATED
To activate the master function, switch the unit first on and then
ITA
ENG
FRA
ESP
DEU
POR
J1
J2
J3
J4
J5