Allmatic HYPER 400 Handmatig - Pagina 9
Blader online of download pdf Handmatig voor {categorie_naam} Allmatic HYPER 400. Allmatic HYPER 400 16 pagina's. Ambidextrous irreversible operator for swing door gates
2
3
4
5
5.1 CHECKS ON THE GATE
Before proceeding to the installation of the motor it is recommended to check the following on the gate:
•
The gate must be level
•
The gate must be in good condition
•
The gate must not have protuberances that collide with the ground or other objects
•
The gate must not hit or crawl the ground at any point of the race
•
The gate must be easily opened and closed for the full width of its run and must be supported only by its hinges
•
The gate must meet the weight and size requirements indicated in this manual
5.2 PREPARATION OF THE INSTALLATION SITE
2
3
4
5
Prepare on the installation site the ducts for the passage of motor cables.
The cables for the connection of the various devices in a typical plant are listed in the table below and must be suitable for the type
of installation, for example we recommend a cable type H07RN-F for outdoor installation.
TABLE 6 - Cables to be used
CONNECTION
Power supply line
Motor
Flashing light
Photocell - transmitter
Photocell - receiver
Key selector
* If the cable exceeds 10 m, a cable with a larger section must be used and a safety grounding must be installed near the auto-
mation.
6-1624982 - rev.1 - 20/05/2021
6
7
8
9
6
7
8
9
CABLE
3 x 1,5mm²
4 x 1,5mm²
2 x 0,5mm²
2 x 0,5mm²
4 x 0,5mm²
4 x 0,5mm²
10
11
12
10
11
12
DUCT
MAXIMUM LENGTH
20 m *
10 m *
20 m
20 m
20 m
20 m
ENG
13
14
15
16
13
14
15
16
17
18
IRD
Data/date Disegnatore/designer
MATER
altern
TRATTA
Progetto/Project:
Via dell'Artigianato 1
DENOM
32026 -Borgo Valbelluna (Bl)
tel. +39 0437 751175 fax +39 0437 751165
[email protected] - www.allmatic.com
Al
Il presente disegno è di proprietà della
17
18
9 / 16