Set up for extraction mode

^ If the on-site ventilation system does
not have a non-return flap, the
non-return flap supplied with the
appliance must be fitted in the
exhaust socket in the motor unit.
^ When using C 150 mm ducting
(recommended), secure the exhaust
connection supplied to exhaust
ducting with a hose clip.
^ When connecting to existing
C 125 mm ducting, place the
reducing collar supplied in the
exhaust connection and secure the
reducing collar to the exhaust
ducting with a hose clip (see also
"Connection for air extraction").
For new installations, 150 mm
ducting is the preferred option as a
reduction in duct diameter affects the
air throughput performance.
^ Place the exhaust ducting on the
exhaust socket for the rangehood.
^ See "Connection for air extraction" for
further instructions on fitting the
ducting.