Miele DA 3496 EXT Bedienings- en installatie-instructies - Pagina 40

Blader online of download pdf Bedienings- en installatie-instructies voor {categorie_naam} Miele DA 3496 EXT. Miele DA 3496 EXT 48 pagina's.
Ook voor Miele DA 3496 EXT: Bedienings- en installatie-instructies (48 pagina's)

Miele DA 3496 EXT Bedienings- en installatie-instructies

Electrical connection

All electrical work should be
undertaken by a suitably qualified
and competent person in strict
accordance with current national and
local safety and building code
regulations. Installation, repairs and
other work by unqualified persons
could be dangerous, for which the
manufacturer cannot be held liable.
Ensure power is not supplied to the
appliance until after installation or
repair work has been carried out.
The rangehood must be connected to a
suitably earthed socket (AC 230 V,
50 Hz).
For extra safety it is advisable to install
a residual current device (RCD) with a
trip current of 30 mA.
Connection of this appliance should be
made via a suitable isolator which
complies with national and local safety
regulations and the On-Off switch
should be easily accessible after the
appliance has been built in.
If the mains socket is not accessible
after installation, an additional means of
disconnection must be provided for all
poles. There must be an all-pole
contact gap of 3 mm in the switch
(including switch, fuses and relays
according to EN 60335).
The connection data is given on the
data plate (See "After sales service").
Ensure that this data matches the
household mains supply.
40