If the exhaust ducting is to run through
rooms, ceiling space etc., where there
may be great variations in temperature
between the different areas, the prob-
lem of sweating or condensation will
need to be addressed.
The exhaust ducting will need to be
suitably insulated.
In addition to insulating the exhaust
ducting we recommend that a suitable
condensate trap is also installed to col-
lect and evaporate any condensate
which may occur.
When installing a condensate trap en-
sure that it is located vertically and if
possible directly above the exhaust
connection.
25