Example 1
Configuring exhaust ducting made from steel for the PT 825x series tumble dryer:
L1, L2:
each 9' 10" (3 m) steel piping
B1, B2:
each 90° concertina pipe elbow (r = 2d)
B3:
90° elbow (r = d)
L2
B3
L1
B1
1. Total pipe length
Steel pipe
Steel pipe
90° concertina pipe elbow
(r = 2d)
90° concertina pipe elbow
(r = 2d)
90° elbow (r = d)
Total pipe length
* Substitute pipe lengths according to Table 1
2. Pipe diameter depending on total pipe length
For the calculated total pipe length of 46' 11" (14.3 m) of a PT 825x, a minimum pipe di-
ameter of 6" (150 mm) is specified for the exhaust ducting according to Table 2.
Supply air, exhaust, and ventilation cross-sections
B2
L1 = 9' 10" (3.0 m)
L2 = 9' 10" (3.0 m)
B1 = 10' 6" (3.2 m)*
B2 = 10' 6" (3.2 m)*
B3 = 6' 3" (1.9 m*)
46' 11" (14.3 m)
9