Risk of explosion due to an
incorrect conversion.
If the conversion to another type of
gas is carried out incorrectly, it may
result in gas leakage.
Conversion from one type of gas to
another must only be undertaken by
an approved and registered gas
installer in strict accordance with
current local and national safety and
building regulations. The installer is
responsible for ensuring that the
appliance functions correctly when
installed.
When converting to another type of
gas, both the main and small jets
need to be changed.
11199440-01

Converting to another gas type

Jet table

The jet markings refer to a ¹/₁₀₀ mm
bore diameter.
Natural gas
Small burner
Medium burner
Large burner
Wok burner
Liquid gas
Small burner
Medium burner
Large burner
Wok burner
Main jet
Small jet
0.76
0.39
0.94
0.42
1.20
0.54
2x 1.07 / 0.72
0.42
0.52
0.23
0.66
0.36
0.81
0.42
2x 0.70 / 0.46
0.25