Safety distances to the sides and
back of the appliance
The minimum distance shown below
must be maintained between the back
edge of the cooktop and a tall unit or
wall.
Ideally the cooktop should be installed
with plenty of space on either side.
There may be a wall at the rear or a tall
unit or wall on one side (right or left),
taking into account the distances
below. On the other side, however, no
tall unit or wall should stand closer than
300 mm to the edge of the cooktop.
Before installing the cooktop, check
that the below clearance requirements
are met.
Minimum horizontal distance from the
back edge of the cooktop to a
combustible surface:
50 mm.
Minimum horizontal distance from the
right edge of the cooktop to a
combustible surface:
50 mm.
Minimum horizontal distance from the
left edge of the cooktop to a
combustible surface:
50 mm.
11274160-02
Minimum safety distance underneath
the cooktop
To ensure sufficient ventilation to the
cooktop, a minimum distance must be
left between the underside of the
cooktop and any oven, interim shelf or
drawer.
The minimum gap between the
underside of the cooktop and
- the top edge of an oven: 2 mm
- the top edge of an interim shelf:
2 mm
- the top edge of a drawer: 5 mm
- the base of a drawer: 75 mm
Interim shelf
It is not necessary to fit an interim shelf
underneath the cooktop but one may
be fitted if you wish.
Leave a gap of 10 mm at the back
between the cabinet and the interim
shelf to accommodate the power
cable.
A gap of 20 mm is recommended at the
front between the cabinet and interim
shelf for better ventilation of the
cooktop.
Installation