• Analogue Power Tube Current Monitors. In order to provide constant current (bias) monitoring for the power
tubes, Allnic uses a separate analogue current meter for each tube. The meters make it exceptionally easy to see
the status of each tube at any time and to respond immediately to any variation in bias by use of the bias control
knob for the relevant tube. The meters offer a simple, unambiguous indication of each tube's status compared
to conventional LED bias monitors.
• "On-the-Fly" Triode/Tetrode Switching. Switching between triode and tetrode operation can be done "on-the-
fly" at any time while the amplifier is in use.
• Beautiful 20KHz square wave response. See Figures 1-3.
Fig.1 Square Wave 50Hz*
• As are all Allnic Audio products, the M-3000 MK 3 is fully RoHS (EU Reduction of Hazardous Substances
regulation) compliant in construction and materials.
WHAT'S IN THE BOX?
Please check that the shipping box (or each one of them if you purchased a pair) contains the following:
•
One (1) each Allnic M-3000 MK 3 monoblock power amplifier
•
One (1) each 15 amp IEC type power cord
•
One (1) Owner's Manual
Note:
1)
The M-3000 MK 3 ships with the tubes installed.
2)
The M-3000 MK 3 will work with most IEC type aftermarket power cords. Allnic power cables will make
an excellent match. Of course, only you can determine the power cord that works most synergistically
with the M-3000 MK 3 in your system.
3)
Be sure the M-3000 MK 3 is labeled for the AC voltage of your location. If it is not, DO NOT connect it
to your AC outlet. Please contact your Allnic dealer.
We advise that you keep the boxes and other packing materials that your M-3000 MK 3 came in. It will be
useful if you sell your M-3000 MK 3 or in the unlikely event you need to ship it for service.
SAFETY
•
Remove ALL protective cushioning material (cardboard around the tubes) inside the tube chimneys
before operation. The tube chimneys should contain NOTHING except the tubes
leave the "O" rings on the small tubes, if any; some prefer the sound with the O rings on).
•
Disconnect the power cord by pulling the plug, not the cable.
•
Do not attempt any repairs. Do not remove the unit's chassis cover without specific authorization from
your Allnic dealer.
*
Measured by LEADER LAG-126 Audio Signal Generator and KENWOOD CS-4125 Oscilloscope.