PREPARATION AND UsAGE OF THIs DEVICE
Prior to using the device for the first time, we recommend cleaning it as described in the section «Cleaning and Dis-
infecting».
1. Assemble the nebuliser kit (Fig. B). Ensure that all parts are complete.
2. Fill the nebuliser with the inhalation solution as per your doctor's instructions (Fig. D). Ensure that you do not
exceed the maximum level.
3. Connect the nebuliser (3) with the air hose (2) to the air hose connector (1c) of the compressor (1), as shown in
figure C. Connect the AC adapter (8) to the AC adapter socket (1e) of the device and plug the power plug of AC
adapter into the wall socket.
4. Switch the ON/OFF switch (1d) to position «I» to turn on the device and place the mouthpiece (4) in the mouth or
fit one of the face masks over mouth and nose.
- The mouthpiece gives you a better drug delivery o the lungs.
- Choose between adult (6) or child face mask (7) and make sure that it encloses the mouth and nose area com-
pletely.
- Use all accessories including the nose piece (5) as prescribed by your doctor.
5. Breathe in and out calmly during the therapy. Sit in a relaxed position with the upper body upright. Do not lie down
while inhaling. Stop inhalation if you feel unwell.
6. After completing the inhalation period recommended by your doctor, switch the ON/OFF switch (1d) to position «O»
to turn off the device. Disconnect the AC adapter (8) from the wall socket and from the device.
7. Disconnect the air hose (2) from the nebuliser (3) and from the air hose connector (1c) of the device.
8. Empty the remaining medication from the nebuliser and clean the device as described in the section «Cleaning and
Disinfecting».
This device was designed for intermittent use of 30 min. On / 30 min. Off.
Switch off the device after 30 min. use and wait for another 30 min. before you resume treatment.
FAsTERJET NEBUlIZER (fig. E)
This compressed air system for aerosoltherapy is equipped with the innovative Fasterjet nebuliser with a breath-en-
hanced valve system. This enables the correct quantity of medication to be featured to the respiratory capacity of each
patient. The valve controls the flow of medication during inhalation, thus reducing medication loss during exhalation.
Fasterjet increases the quantity of inhaled medication. Fasterjet is capable of nebulising efficiently all medications for
inhalation therapy. A synchronized functioning of the nebuliser is possible only by using the mouthpiece with expira-
tory valve. In order to increase nebulising speed, it is recommended to remove the inhalation valve (blue support) (3b)
when using a mask or a nose piece.
ClEANING AND DIsINFECTING
Thoroughly clean all components to remove medication residuals and possible impurities after each treatment. The
compressor (1) and the air hose (2) should be cleaned with a clean, moist cloth.
• Always wash your hands well before cleaning and disinfecting the accessories.
• Do not expose the compressor to water or heat.
• Replace the air hose for each treatment with a new patient or in case of impurities.
Always unplug the AC adapter from the power supply before cleaning.
Cleaning with water
Wash all nebuliser components (except air hose) under warm tap water (max 60 °C) for about 5 minutes adding if
necessary a small quantity of detergent following dosage and use limitations as provided by detergent manufacturer.
Rinse thoroughly making sure that all deposits are washed away and leave to dry.
8