Getting Started
To access the service menu, press and hold the Adjust Control/Select Button for 5 seconds, then
release. Rotate the knob to scroll through the menu items. Press and release the control to access
the options and information within each menu item.
Rotate the control to scroll or change value. Press and release control to save selection. After 5
seconds of inactivity, the menu will time out and the selection will be saved.
Menu Item
HOUR MTR
ENG OIL
COMP OIL
RPM DISP
RPM SET
STOP TIME
MIN PRES
MAX PRES
SOFT WARE
FACT RSET
Codes Shown on EnPak Remote Control Panel Display
You could see a code show up on the EnPak screen to let you know there is some type of issue.
Check the manual for error code reference to help repair the issue. Resetting of Charge/Weld codes
can be done by either: changing position of the charge/weld switch; change positions of the process
select switch; cycle unit power off/on. Resetting of Air Compressor codes can be done by switching
the compressor Off, then On.
(continued)

Service Menu

Selectable Item
Option(s)
– –
OIL HOUR
OIL SET
OIL RSET
OIL HOUR
OIL SET
OIL RSET
– –
AUTO
3600
2 to 30 min
90 psi up to 10 psi less
than max pressure
175 psi down to 10 psi
greater than min pressure
– –
RSET YES
RSET NO
Description
Displays the current Engine Hours.
Displays the current oil change countdown.
Sets the oil change interval.
Resets the oil change countdown.
Displays the current oil change countdown.
Sets the oil change interval.
Resets the oil change countdown.
Displays current engine RPM.
Enables auto speed function.
Locks engine speed at 3600 RPM.
Unit idle time before auto stop (adjustable in 1 min increments).
Minimum pressure to start air compressor (adjustable in 1 psi
increments).
Maximum pressure to stop air compressor (adjustable in 1 psi
increments).
Displays the current revision of firmware installed.
Resets all settings to factory defaults.