Miller Deltaship 502 Gebruikershandleiding - Pagina 15

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Miller Deltaship 502. Miller Deltaship 502 28 pagina's. Arc welding power source

Miller Deltaship 502 Gebruikershandleiding

3-11. Remote 6-Socket Receptacle RC8 Information

3-12. Electrical Service Guide

Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Rating In Amperes
Min Input Conductor Size In AWG
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG
Reference: 2005 National Electrical Code (NEC) (including article 630)
1 If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse.
2 "Time-Delay" fuses are UL class "RK5" .
3 "Normal Operating" (general purpose - no intentional delay) fuses are UL class "K5" (up to and including 60 amp), and UL class "H" ( 65 amp and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.
Socket
1
2
3
4
5
6
1
2
Time-Delay
3
Normal Operating
4
4
Socket Information
Motor voltage; 0 to +21 volts dc with motor M1 running.
Gas valve voltage; +24 volts dc when gun is triggered or when purging
gas.
Trigger/Jog; Normally +15 volts dc; 0 volts dc when gun is triggered and
+ 7 volts dc when Jog switch PB1 is pressed.
Voltage and wirefeed speed; −2 to +3 volts dc output command for volt-
age and wire speed.
Remote circuit common.
Motor M1 and gas valve GS1 return (−).
50 Hz Three Phase
380
49
60
70
8
208 (63)
8
OM-227 512 Page 13