3-5. Duty Cycle Charts

200
150
100
50
0
10
200
150
100
50
0
10
Diversion 165 Models
% Duty Cycle
20% Duty Cycle at 150 A AC/DC
2 Minutes Welding
Diversion 180 Models
230 VAC
115VAC
% Duty Cycle
20% Duty Cycle at 150 A AC/DC
2 Minutes Welding
Duty cycle is percentage of 10
minutes that unit can weld at rated
load without overheating.
NOTICE − Exceeding duty cycle
can damage unit and void warranty.
8 Minutes Resting
8 Minutes Resting
100
232 918-B
100
246 526-A
OM-246 522 Page 13