System Settings
To Change System Settings
Step 1: Rotate Adjust Control/Select button to select a setting.
Step 2: Press Adjust Control/Select button on desired setting.
Step 3: Rotate Adjust Control/Select button to update the setting.
Step 4: Press Adjust Control/Select button to
save the setting, or press the Back button to discard setting change.
Press HOME button to return to Home screen.
System Settings Item
Selectable Item Options
Power Priority
Air Pressure Min
90 psi up to 10 psi less than max pressure
Air Pressure Max
175 psi down to 10 psi greater than
min pressure
Air Response
Low, Medium, High
Auto Start/Stop
Enabled / Disabled
NOTE: Enabled is recommended.
Auto Start/Stop Time
2 to 30 minutes
RPM
Auto
2800
Screen Brightness
1 to 10
Hydraulic Max Pressure
2000 to 4000 psi
NOTE: Compensator is factory set to 3300 psi.
Hydraulic Max Flow
3 to 20 gpm NOTE: Set to 8 gpm for most cranes.
Crane Remote Type
0V to 12V Step
0V to 12V Proportional
12V to 0V Proportional
Crane Voltage Threshold
0.1V to 12V
NOTE: If unit does not idle down
when all loads are off, increase the
Crane Voltage Threshold slightly
until unit idles down.
Tap To Start (Weld Units Only)
Enabled / Disabled
NOTE: Enabled is recommended.
Safe Start
Enabled / Disabled
NOTE: Enabled is recommended.
Power Time
1 to 20 minutes
Air Compressor Operation
1
Air Compressor Operation Button
While in the Home screen and the Weld screen, press
the Air Compressor Operation button to toggle the
compressor output.
Compressor is On when AIR icon is white, and Off when
AIR icon is gray.
NOTE: Weld output and generator power may be reduced when the air
compressor is on.
Description
Optimizes output priority between hydraulics and air compressor.
Minimum pressure to start air compressor (adjustable in 1 psi increments).
Maximum pressure to stop air compressor (adjustable in 1 psi increments). Lower is better to conserve
engine power.
Optimizes the response when a heavy air load is applied instead of waiting to turn the air compressor
on when the minimum psi threshold is met.
Engine will stop when no load is applied for the Auto Start/Stop Time threshold. Engine will start again
when a load is applied.
How long the unit will run before Auto Stopping with no load.
Idles at 1800 rpm and adjusts based on demand.
Locked at 2800 rpm.
Changes the brightness of the display.
Maximum hydraulic pressure set point.
If setting maximum pressure above 3300 psi factory setting, a Factory Authorized Service agent will
need to adjust compensator.
Maximum hydraulic flow set point.
Never set hydraulic flow higher than crane rating.
Chooses crane remote signal type.
Optimizes voltage threshold for OFF vs ON.
•For "0V to 12V Step" and "0V to 12V Proportional" crane remotes, set Crane Voltage Threshold to 0.1V.
•For IMT Cranes, set Crane Voltage Threshold higher than 0.1V to allow unit to idle down when crane
is not enabled.
•For "12V to 0V Proportional" crane remotes, set Crane Voltage Threshold to slightly less than 12V.
Enabled: Restarts engine while in Auto Stop mode by tapping welding rod to workpiece.
Disabled: Engine does not restart by tapping welding rod.
Enabled: When in weld screen or battery charge mode, unit will automatically switch to Chassis Power
when chassis battery voltage drops below 12.3 volts.
Disabled: Unit does not automatically switch to Chassis Power.
Adjustable timeout for automatic switch to Chassis Power.