Burkert 1062 Gebruiksaanwijzing - Pagina 5

Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Burkert 1062. Burkert 1062 8 pagina's.

1062 Version
Plug
PG
1062
Unscrew cover
.
Pull cable through PG
cable gland
, peel-off 100 mm
from the cable and connect
according to wiring diagram
(see next page).
Install cable into guide on bottom
of body
.
Fasten PG cable gland
Screw back cover
Only valve 2031 with C actuator:
Label specification tag
If the position feedback indicator in operation
should be changed to another valve, set both
trip cams to the distances shown in the figure.
NOT valve 2031 with C actuator:
Label specification tag
Stroke must not be adjusted (self-adjusting).
In case the position feedback indicator in operation
should be changed to another valve, set the lower
trip cam to the height of 35.5 mm.
POSITION FEEDBACK 1062
Green
.
.
.
.
-5-
Red
Yellow
4,6 mm
26 mm