4-4. Duty Cycle And Overheating

Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
duty cycle before welding.
NOTICE − Exceeding duty cycle
can damage unit and void warranty.
100% Duty Cycle At 450 Amperes
60% Duty Cycle At 565 Amperes
6 Minutes Welding
4 Minutes Resting
Continuous Welding
Overheating
A/V
0
15
OR
Reduce Duty Cycle
Minutes
duty1 4/95 − SA-181 560