Miller M-10 Gebruikershandleiding - Pagina 16
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Miller M-10. Miller M-10 48 pagina's. Air-cooled guns for gmaw and fcaw welding
Ook voor Miller M-10: Gebruikershandleiding (8 pagina's)
4-3. Process/Polarity Table
Process
Process
GMAW − Solid wire with shield-
ing gas
FCAW − Self-shielding wire −
no shielding gas
4-4. Changing Polarity
1
4-5. Internal Shielding Gas Supply
3
2
4
OM-1328 Page 12
Polarity
Polarity
DCEP − Reverse polarity
DCEN − Straight Polarity
1
.
If a welding arc is not
established within one
second, the gas solenoid
turns off to conserve
shielding gas.
Cable Connections
Cable To Gun
Connect to positive (+) out-
put terminal
Connect to negative (−)
output terminal
2
Cable To Work
Connect to negative (−) output
terminal
Connect to positive (+) output
terminal
1
Lead Connections For Direct
Current Electrode Positive
(DCEP)
2
Lead Connections For Direct
Current Electrode Negative
(DCEN)
Always read and follow wire
manufacturer's recommended po-
larity, and see Section 4-3.
Close door.
Ref. 220 579-A
1
Internal Shielding Gas Bottle
The internal shielding gas bottle is
for CO
gas only.
2
2
Pressure Gauge
3
Regulator
4
Internal/External Transfer
Switch
The Internal/External Transfer
switch allows changing between
the internal or external shielding
gas supply.
Place switch in the Internal Gas
Bottle position.
Ref. 803 811-A