Burkert 8791 Extra instructies - Pagina 6

Blader online of download pdf Extra instructies voor {categorie_naam} Burkert 8791. Burkert 8791 12 pagina's. External position feedback option with inductive proximity switch
Ook voor Burkert 8791: Montagehandleiding (16 pagina's), Montagehandleiding (16 pagina's)

Burkert 8791 Extra instructies
DANGER!
To prevent the risk of explosion, observe not only the safety
instructions in the operating instructions for operation in the
potentially explosive atmosphere, but also the following:
▶ Specifications on the type label concerning temperature class,
ambient temperature, degree of protection and voltage.
▶ Do not use device in areas where there is gas or dust with a
lower ignition temperature than indicated on the type label.
▶ Installation, operation and maintenance may be performed by
qualified technicians only.
▶ Observe the applicable safety regulations (also national safety
regulations) as well as the general rules of technology for con-
struction and operation.
▶ Do not repair the device yourself, but replace it with an equiva-
lent device. Repairs may be performed by the manufacturer
only.
▶ Do not expose the device to any mechanical and/or thermal
loads which will exceed the limits described in the operating
instructions.
▶ Use only cable and line entry points which have been approved
for the respective application area and which have been
screwed into place according to the associated installation
instructions.
▶ The cable glands may be used for the insertion of permanently
installed cables and lines only.
▶ Close all unnecessary cable glands with lock screws approved
for the potentially explosive atmosphere.
6
english
▶ Use pre-assembled cable glands according to the installa-
tion instructions supplied by the gland manufacturer. Before
start-up in the potentially explosive atmosphere, check
whether the cable gland, as described in the associated
installation instructions, has been installed.
4.1

Special conditions of use

▶ Do not use the device in dust atmospheres in which inten-
sive charging processes can be expected.
▶ Use the device only in an area with at least degree of soil-
ing 2, as defined in IEC 60994-1.
▶ Ensure that the transient protection has been set to a value
which does not exceed 140 % of the measured peak voltage
value at the supply connections of the device.
▶ If devices feature a circular plug connection (multipole), the
mating plug will be provided by the end user and is not an
object of the approval. The mating plug must satisfy the
relevant requirements of the IEC 60079-0, IEC 60079-7 and
IEC 60079-31 and must have at least housing degree of
protection IP65 according to IEC 60529.
▶ If devices feature a circular plug connection (multipole), use
a special locking clip which prevents the plug from being
loosened without a tool.
BVS 16 ATEX E 118 X
Particular safety instructions