Miller Elite Series Gebruikershandleiding - Pagina 18

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Miller Elite Series. Miller Elite Series 32 pagina's. With external grind button auto-darkening helmets
Ook voor Miller Elite Series: Gebruiksaanwijzing (32 pagina's), Handmatig (20 pagina's), Gebruikershandleiding (32 pagina's)

Miller Elite Series Gebruikershandleiding
5-6.

Sensitivity Control

2
1 Sensitivity Adjustment Buttons
2 Mode Control Button
Use control to make the lens more respon-
sive to different light levels in various welding
processes. Use a Mid-Range or 30-50%
sensitivity setting for most applications.
It may be necessary to adjust helmet sensi-
tivity to accommodate different lighting condi-
tions or if lens is flashing On and Off.
The sensitivity ranges for each mode are as
follows:
Weld, Cut, X-Modes - 0–10
Grind Mode - No sensitivity adjustment
Do not weld in the Grind mode; the
lens will not darken.
Sensitivity Adjustment Procedure
Adjust helmet sensitivity in lighting con-
ditions helmet will be used in.
� Press Mode button to turn helmet On.
� Press Mode button to select desired
function: Weld, Cut, or X-Mode.
Stick Electrode
Short Circuiting (MIG)
Pulsed And Spray (MIG)
Gas Tungsten Arc (TIG)
Plasma Arc Cutting/Welding
OM-288930 Page 16
(R)
MEMO(B)
Recommended Sensitivity Settings
TIME
1
� Use Sensitivity Less and More buttons
to adjust sensitivity control to lowest
setting.
� Face the helmet in the direction of use,
exposing it to the surrounding light
conditions.
� Press sensitivity More button until the
lens darkens, then press Less button un-
til lens clears. An alternative method is
to press and hold the Less button until
the lens clears.
Helmet is ready for use. Slight readjustment
may be necessary for certain applications or
if lens is flashing on and off.
Reduce Sensitivity setting if lens stays
dark longer than Delay setting.
This lens also features AutoSense
lows users to push and hold only one button
for the lens to adjust sensitivity to the proper
setting while in Weld mode.
To initiate AutoSense, face helmet toward
workpiece and push and hold the Less/Auto-
Sense button until screen indicates that it is
adjusting.
Mid-Range
Low/Mid-Range
Mid-Range
Mid/High-Range
Low/Mid-Range
ARC
COUNT
MEMO
2
1
, which al-