INSTALLATION
Water Pressure
A minimum of 20 psi (1.4 bar) of water pressure is required for
the regeneration valve to operate effectively.

Electrical Facilities

An uninterrupted power supply is required. The control uses a
transformer to supply 12 VDC. Please make sure your voltage
supply is compatible with your unit before installation.
Existing Plumbing
Condition of existing plumbing should be free from lime and
iron buildup. Piping that is built up heavily with lime and/or iron
should be replaced. If piping is clogged with iron, a separate
iron filter unit should be installed ahead of the system.
Location Of System And Drain
The system should be located close to a drain to prevent air
breaks and back flow.
Outdoor Locations
When the water conditioning system is installed outdoors,
several items must be considered.
• Moisture — The system is not designed to withstand
extreme humidity or water spray from below. Examples
are: constant heavy mist, near corrosive environment,
upwards spray from sprinkler.
This unit is for dry location use only unless used
CAUTION
with a Listed Class 2 power supply suitable for
outdoor use.
• Direct Sunlight — The materials used will fade or
discolor over time in direct sunlight. The integrity of the
materials will not degrade to cause system failures. If
it is necessary to locate the system in direct sunlight, a
protective outdoor cover (P/N 61882) over the valve and
controller is necessary.
• Insects — If installing in an environment that may expose
the system to insects or other small animals, a protective
cover is required. The protective outdoor cover (P/N
61882) has been designed to keep all but the smallest
insects out of the critical areas. The cover should be
installed securely in place.
Bypass Valves
Always provide for the installation of a bypass valve if unit is not
equipped with one.
Water pressure is not to exceed 125 psi (8.6 bar),
CAUTION
water temperature is not to exceed 110°F (43°C),
and the unit cannot be subjected to freezing
conditions.
The system must be depressurized before
WARNING:
removing any connections for servicing.

Installation Instructions

1. Place the media tank where you want to install the unit.
Make sure the unit is level and on a firm base.
2. During cold weather, the installer should warm the valve to
room temperature before operating.
3. All plumbing should be done in accordance with local
plumbing codes. The pipe size for a residential drain line
should be a minimum of 1/2" (13 mm). Backwash flow rates
in excess of 7 gpm (26.5 Lpm) or drain line length in excess
of 20' (6 m) require 3/4" (19 mm) drain line. Commercial
drain lines should be the same size as the drain line flow
control.
4. Soldering of joints near the drain port must be done prior to
connecting the Drain Line Flow Control fitting (DLFC). Leave
at least 6" (15 cm) between the DLFC and solder joints when
soldering pipes that are connected on the DLFC. Failure to
do this could cause interior damage to the DLFC.
5. Plumber tape is the only sealant to be used on the drain
fitting.
6. Make sure that the floor is clean beneath the salt storage
tank and that the tank is level.
7. Add 2 gallons of water to the brine tank.
8. On units with a bypass, place in bypass position. Turn on the
main water supply. Open a cold soft water tap nearby and let run a
few minutes or until the plumbing is free from foreign material
(usually solder) that may have resulted from the installation. Once
clean, close the water tap.
9. Slowly place the bypass in service position and let water flow into
the mineral tank. When water flow stops, slowly open a cold water
tap nearby and let water run until the air is purged from the unit.
10. Plug the transformer into an electrical outlet.
NOTE: All electrical connections must be connected
according to local codes. Be certain the outlet is uninterrupted.
Figure 1 Residential Air Check Valve
Electrical Connection
The controller operates on 12-volt DC power supply. This
requires use of the supplied power adapter included with your
system.
NOTE: The power source should be constant. Be certain the
power adapter is not on a switched outlet. Power
interruptions longer than eight hours may cause the
controller to lose the time setting. When power is
restored, the time setting must then be re-entered.
60002 Rev E
Fleck 5800 XTR2 Quick Start Manual • 2