1.9 Routine cleaning and maintnance

The appliance must only be cleaned after the power supply upstream from the appliance has been
disconnected.
During the maintenance operations, the cable and the plug must be always visible and accessible for
the operator who is performing the operations.
The routine and preventive maintenance essentially entails cleaning the stainless steel parts with warm
water and mild soap on a weekly basis, and then rinsing and drying these thoroughly. Do not use direct
jets of water. We recommend cleaning the fins of the refrigerating unit's condenser at least every three
months. These operations must be performed by qualified personnel.
WARNING:
Under no circumstances should you use abrasive or corrosive cleaning products.
WARNING: Do not accelerate the defrosting process using utensils such as scourers, brushes or
sharp metal scrapers.
Bleach, hydrochloric acid and other compounds containing chlorine will damage the stainless steel.
The floor under the appliance must not be washed with corrosive substances that could produce
appliance-damaging vapours.
When cleaning, do not wash the appliance with jets of water.
WARNING: Do not damage the refrigerant circuit.
It is forbidden to remove the safety guards.
It is forbidden to use open flames to check for gas leaks.
Smoking is prohibited.

1.10 Unplanned maintenance

Before carrying out any maintenance work, put the appliance in a safe condition. Unplanned maintenance
is carried out in the event of a fault or malfunction. It must only be performed by qualified personnel
and with the appliance disconnected from the power mains. In this case, repairs or replacements might
be required. The faulty parts must only be replaced with materials and components that are identical
to the originals or have been specified by the Supplier. The use of unsuitable materials can make
the machine non-compliant with the safety standards. The manufacturer declines all responsibility for
damage resulting from work carried out by unqualified or unauthorised technicians.
Should any anomalies occur (short circuits, mechanical failures, electric cable deterioration, a smell
of gas indicating a possible leak, etc.), the person in charge of normally operating the machine must
immediately switch off the appliance, unplug it from the power mains and secure the work area.
Warning: the appliances contain flammable refrigerant gas (e.g. R290).
R290 gas is a potentially flammable and explosive type of gas. Therefore, it is absolutely necessary to
take every precaution to avoid any danger related to the nature of this gas during routine and unplanned
operations. Use suitable tools and avoid using open flames and electrical tools.
If the user replaces components or modifies the appliance without written permission from the
Manufacturer, or uses unauthorised spare parts, the guarantee will immediately become null and void.

1.11 Disposal

At the end of its service life, the appliance must be disconnected from the power mains before the
various components are disassembled. Special care must be taken to avoid the risk of injury related to
the shape and weight of each component.
The symbol on the product indicates that it should not be considered as domestic waste. The
appliance must be disposed of in accordance with the laws in force, most especially in regards to
the disposal of the refrigerant. The various parts (electrical components, rubber hoses, cable
sheaths, etc.) must be sorted for recycling in order to make the best possible contribution whilst
protecting the environment and complying with the laws in force.