6. Starting of the DWM
To start the DWM, one must connect the supply tubes and carry out the rinsing of cartridges.
Step 1 - Connect the supply tubes as shown in Figure 2.
the blue tube - from the connection assembly to the inlet manifold assembly;
the red tube - from the drain clamp to the drain fitting of the manifold assembly;
the white double tube - from the clean water tip to the outlet fitting of the manifold assembly.
Step 2 - Install the filter cartridges
Figure 7
For rinsing
6
Figure 6a
Figure 6b
Position of the cartridges in the DWM
How to connect the tubes (Fig. 6a)
Pull out the locking clip from under the plastic bushing,
insert a pre-dampened end of the tube into the fitting
bushing until it stops at a depth of about 15 mm, and
install the clip into the place.
Check the holding strength of the tube fixing:
the tube should not be removable by a force of 8-10 kgf
applied.
Disconnecting the tubes (Fig. 6b)
To disconnect the tube, pull out the locking clip from
under the plastic bushing, and then pull the tube by
clicking on the end of the plastic bushing.
Remove the shrink film and transport seals (if
any) from the cartridges.
Make sure that the inner surfaces of the
connecting flanges of the cartridges are clean
(no coal dust, etc.).
In case of dust, rinse the flange under running
water.
In accordance with (Fig. 8) "Position of the
cartridges in the DWM ", install the cartridges in
the "rinsing" position (the rinsing cap shall be
located under the lid of the water purifier - see.
Fig 1). In order to do this, insert the cartridge
into the corresponding manifold and turn it
clockwise until it clicks (Fig. 7).
To disconnect the cartridge, press the lock
button
counterclockwise.
For operation
Figure 8
and
rotate
the
cartridge