Step 3 - Installation of the mineralizer
Mineralizer can be optionally installed into the clean water collection bowl or on the shutoff device.
Installation of the mineralizer in the collection bowl
•
Remove the cover of the collection bowl.
•
Insert the mineralizer in the bracket of the collection bowl aligning the tabs on the mineralizer with the
slots in the bracket, and turn it all the way counterclockwise, as shown in Fig. 9.
Put the cover of the collection bowl with the mineralizer set back to the place.
•
Installing of the mineralizer on the shutoff device
•
Insert the mineralizer in the bottom of the shutoff device aligning tabs on mineralizer with the slots on
the bottom and turn it all the way counterclockwise, as shown in Fig. 10.
Step 4 - Rinse the DWM
•
Open the inlet valve;
•
Insert the tip into the shutoff slot (Fig. 12 a) holding it over the sink;
•
Holding the tip in one hand, put the shutoff device into the sink and leave the water draining out from
the water purifier for 60 minutes;
•
Disconnect the tip from the shutoff device by clicking on the button at the end face of the shutoff device
(Fig. 12b);
•
Close the inlet valve;
•
Install the cartridges in the "operation" position;
•
Open the inlet valve;
•
Insert the tip into the cover slot of the collection bowl;
•
Wait for the water to fill the collection bowl and flush it;
•
Repeat the last procedure 2 times.
At the last stage of preparing drinking water of the premium class, a natural mineral is used in
RO-31 (DWM-31) allowing to achieve the necessary strict dosing of nutrients in the purified water.
However, since the mineral is quite fragile, a certain amount of dust can be formed during transportation,
which must be washed off at the first start of the water purifier.
ATTENTION! Do not drink the water, which was obtained in the result of rinsing.
During the first week of operation, check the DWM for leaks every day. In the first week of the water purifier
operation, there may be a noise associated with the release of air from the interior of the water purifier
when switching automatic valve. After some time, this process will stop. This is not a malfunction.
Figure 9
Figure 10
7