AQUAPHOR S550 P1 Bedieningshandleiding - Pagina 7

Blader online of download pdf Bedieningshandleiding voor {categorie_naam} AQUAPHOR S550 P1. AQUAPHOR S550 P1 20 pagina's.

AQUAPHOR S550 P1 Bedieningshandleiding
Interruption of a running regeneration cycle (only used
for system diagnostics).
4. Press and hold the button
regeneration process starts.
5. The display will show the stage number (for example –
01).
6. If the controller does not move to the next stage with-
in 20 seconds, press and hold the button
2 seconds, the controller will proceed to the next stage.
NOTE: Each regeneration step can only be interrupted
once it has started. To move to the next stage of the re-
generation mode, press
Enable / disable the enhanced
regeneration function.

Controller Screen

for 5 seconds after the
for about
.
The main screen displays the volume of water in liters (or gallons) that will be
treated by the softener before the next automatic regeneration. On average, an
adult spends 280 l water per day. The volume of water until the next water re-
generation is indicated in hundreds or thousands of liters, depending on the val-
ue. For example, the number 33 would mean 33 000 l if x 1000 is shown on the
display at the same time, and 3300 l if this indicator is inactive.
During regeneration, the number of the stage currently in progress will flash on
the main screen:
01 – First backwash.
02 – salt regeneration / slow washing.
03 – second backwash
04 – topping up the brine tank.
HO – return to working position. After the regeneration is completed, the display
will again show the amount of water until the next regeneration in hundreds of
gallons or hundreds / thousands of liters. The duration of regeneration is 30–
40 minutes.
Regeneration progress indicator. Indicates that the softener is auto-regenerat-
ing or a manual regeneration has started.
Water consumption indicator. "Droplets" on the display "run" as water flows
through the softener. It is convenient for monitoring water consumption and for
detecting water leaks.
This function can be performed as part of the service in
the following cases:
• operation of the softener on water containing dis-
solved iron,
• with a decrease in the quality of cleaning due to water
consumption, significantly exceeding the resource of
the softener before regeneration,
• with virtually no regeneration due to insufficient salt,
lack of input water or electricity.
In this mode, the softener will be flushed every other day,
consuming 1.6 kg salt per regeneration. The softener in
the mode of enhanced cleaning from iron should work for
at least 2 weeks. The increased frequency of regenera-
tions will help to remove the accumulated iron in the ion
exchange resin bed. This service procedure is recom-
mended to be carried out at least once a year.
7