Diamond IE140/R9G Gebruiksaanwijzing - Pagina 9
Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Diamond IE140/R9G. Diamond IE140/R9G 9 pagina's. Refrigerated cabinets
Check that the doors close properl
Check that the condenser is clean: You must bear in mind that the cleaner the refrigerator is
the greater the energy saving, particularly the condenser's ribbing. The frequency of this
cleaning will be determined by the characteristics of the premises. If it is dirty, call the technical
support service to clean it.
c) In the event of strange or excessive noise
Check the unit's levelling and that the doors close properly.
Check that there are no objects touching any of the refrigerator's moving components.
Special maintenance
3.2
(Authorised technical personnel)
Condenser cleaning: When cleaning, be careful not to bend the condenser aluminium ribs, as
on the contrary the air will not come through and will not condense, causing serious damage
to the appliance and its repair guarantee will be made void.
Check that the premise's temperature does not exceed that indicated for your cabinet.
The guarantee will be made void if there is insufficient ventilation.
Check that the doors close properly.
Do not disassemble the mobile components guards without first having turned the appliance
off.
Take all the necessary precautions before accessing the area of the condenser unit, given the
existence of high temperatures of some components, with the resulting risk of burns.
If the flexible power cable or cord is damaged, it must be replaced by the manufacturer, after-
sales service or authorised technical personnel in order to prevent risks.
It if is replaced, the earth pin must be positioned again.
If you need to change a cable, you must never use a smaller section.
The electrical connections are carried out with 6.35 mm Faston terminals, protected with
covers.
If it is necessary to disassemble the inner lid of the control panel's electrical installation, it is
extremely important to leave it exactly as it was when reassembling it.
Clean condenser