Burmester 032 Gebruikershandleiding - Pagina 9
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Burmester 032. Burmester 032 16 pagina's. Integrated amplifier
With the exception of the AC mains switch all operating controls are located on the front panel. To operate the unit it
must be connected to the AC supply.
The AC mains switch (19) which turns AC power to the unit on and off is located on the
AC mains switch
rear panel above the AC mains terminal. By switching to the ON position the transformer is
powered up and the unit is in stand-by mode. The stand-by mode is shown by the lightning
of the Stand-by LED (2).
The POWER button (9) turns the unit on and off provided the AC mains switch is in the ON
POWER button
position.
When the amp is ready for operation the alphanumeric display (3) will light up.
In stand-by mode only the stand-by LED (2) lights up.
After switching on the 032, the safety monitoring system takes a few seconds to check all
functions. The speaker terminals and preamp outputs are enabled only, if no errors are
detected.
CAUTION: Always use the POWER button (9) first to switch the unit off, before setting the
AC mains switch (23) to OFF.
The VOLUME knob (8) controls the volume level in 61 steps from 00 (off) to 60 (full
VOLUME knob
volume). If the VOLUME knob is turned slowly, the volume changes step by step. If rotated
quickly, the volume changes in larger increments. The display indicates the selected
volume level.
The VOLUME knob also controls the functions in the SETUP menu.
Inputs are selected by pressing the respective one of the input select buttons (7). The
INPUT select
display (3) indicates the selection.
Pressing the button SURR(ound) (5) activates the input SURROUND IN (12). The signal
SURROUND input
from the SURROUND input is routed directly to the power amp stages, bypassing tone
control and volume control.
Pressing the button labeled MONITOR (15) blocks the direct signal path during recording
MONITOR function
and switches to replaying the just recorded signal. When the monitor function is activated,
the display will add a –M to the selected source name.
The inputs TAPE and SURROUND have no monitor function.
OPERATING CONTROLS
5