Starting the count:
When the questions for all channels are answered the display will show:
ALARM Y/N
The counter displays the sum of fishes passed through the shown channels. The message CAL is
shown after the number whenever calibration is performed for one or more channels shown.
An example, if the display reads:
passed C1 and C3 together. Here are one or both channels in calibration mode. A press on indicator
C3 will hide channel 3 and the result in channel 1 is viewed e.g.:
This means that calibration is at least in progress for channel 1.
If the same indicator (C3) is pressed again, the display will return to show the sum of units C1 and C3:
Now a press on indicator C1 (hide C1) may give this result:
Please note that the text Cal does not follow the number viewed here. This means that there is no
calibration on channel 3. This example shows that the average size on this channel is based on the
former counting operation. No average weight was given for this particular channel.
When the calibration is finished (at least 125 fish) the text Cal will automatically disappear and
AquaScan will show the correct number of fish passed during the calibration.
Pressing the belonging channel-button will stop an alarm (Alarm number, Error message)
Counting pause:
You can temporary stop (pause) the counting with the stop button (0/Stop key). The screen will show:
CONTINUE Y/N
Type in a new average weight or press only Enter to resume counting.
WEIGHT(g) Cx:
Press N and the counter starts counting, see next section.
Press Y if you wish the system to give an alarm (siren) when a given number of
fish have passed. The display will show:
AlarmNbr Cx:
Enter the number of fish for the displayed channel and press
Enter. The counter is asking for the alarm number for each
channel. Press Enter only if no alarm is intended for the given
channel. After all channels are entered the counter will start
counting.
C13: 162 Cal
Press Y to continue counting or
Press N to restart the system and the screen will read:
it means that 162 groups of fish have
C13: 162 Cal
C3: 92
Page 5 of 20
C1: 70 Cal